KEB COMBIVERT F5 MULTI Applications Manual page 265

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Special Functions
Exsample 2
©
KEB Antriebstechnik, 2002
All rights reserved
The drive runs with different speed back and forth and always reverses at the same
points.
Downloadlist:
Set
Parameter
0
Ud01
Password
0
Fr01
Copy parameter set
0-3
oP00
Reference source
0-3
oP01
Rotation source
0
oP02
Rotation setting
1
oP02
Rotation setting
2
oP02
Rotation setting
3
oP02
Rotation setting
0-3
oP10
Max. reference forward
0-3
oP11
Max. reference reverse
0-3
oP28
Acc. time forward
0-3
oP30
Dec. time forward
0
Pn63
Positioning delay
1
Pn63
Positioning delay
2
Pn63
Positioning delay
3
Pn63
Positioning delay
0
Fr02
Parameter set source
0
Fr05
Set activation delay
1
Fr05
Set activation delay
2
Fr05
Set activation delay
3
Fr05
Set activation delay
0
Fr06
Set deactivation delay
1
Fr06
Set deactivation delay
2
Fr06
Set deactivation delay
3
Fr06
Set deactivation delay
0
Fr07
Para. set input selection
0
Fr11
Reset set input selection
0
di11
I1 Function
0
di15
IA Function
0
do04
Condition 1
1
do04
Condition 1
2
do04
Condition 1
3
do04
Condition 1
Name: Basis
KEB COMBIVERT F5
Functional Description
Value
Notes
440
-2: def. cust.para all sets
0: Analog REF
0: dig.(op.2), 0-lim.
1: forward
Set 0: clockwise rotation
0: low speed
Set 1: clockwise rotation positioning
2: reverse
Set 2: counterclockwise rotation
0: low speed
Set 3: counterclockwise positioning
70,0000 Hz
The max. setpoint value must be the
same in all sets.
-1: = see oP.10 The max. setpoint value can be different
for the direction of rotation.
0,10 s
0,10 s
-1: off
0,8 s
Shifting of the position at clockwise
rotation
-1: off
3,1 s
Shifting the position at counterclockwise
rotation
2: terminal binary coded
0,00 s
Additional break between counter-
clockwise and clockwise rotation
0,00 s
This time must be = 0
0,00 s
Additional break between clockwise and
counterclockwise rotation
0,00 s
This time must be = 0
0,00 s
This time must be = 0
1,00 s
Break between clockwise and
counterclockwise rotation
0,00 s
This time must be = 0
1,00 s
Break between counterclockwise and
clockwise rotation
272: I1+IA
0: no input
2048: Set sel.
Initiator signal
2048: Set sel.
Changeover between clockwise and
counterclockwise rotation
0: off
Initiator active: -> set 1
1: on
Positioning completed: -> set 2
1: on
Initiator active: -> set 3
0: off
Positioning completed: -> set 0
Date
04.05.04
Chapter
Section
Page
6
9
33
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: