KEB COMBIVERT F5 MULTI Applications Manual page 58

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Operation
F5-SERVO:
Motor current for zero speed
F5-MULTI:
Rated Frequency
F5-SERVO:
Load motor dependent
parameter
Chapter
Section
Page
4
3
12
Adjustment of the motor current for zero speed according to the data sheet. The
factory setting depends on the motor.
Adjustment range:
Resolution:
Factory setting:
With the adjusted frequency the inverter reaches in controlled operation a maximal
output voltage. The adjustment of the rated motor frequency is typical in this case.
Note: Motors can overheat when the rated frequency is incorrectly adjusted.
During regulated operation (CP.10 = 4 or 5) this parameter has no function.
Adjustment range:
Resolution:
Factory setting:
The basic settings of the inverter correspond to the size of the unit and the respective
motor (see 4.3.7 "Factory Settings"). If the motor data in CP.11...18 are changed, then
CP.19 must be activated once. This re-adjusts the current controller, torque curve and
torque limit. With this, the torque limit is set at the value, that is maximally possible in
the speed range (depending on inverter rated current), but not above the rated motor
torque x 3.
CP.19 = 1 :
Å Pre-adjustment of the motor-dependent control-parameters.
Å The voltage class of the inverter is taken as input voltage.
CP.19 = 2 :
Å Pre-adjustment of the motor-dependent control-parameters.
Å The DC-link voltage / √2 measured at switch on is taken as input
voltage. Thus the frequency inverter can be adapted to the actually
available mains voltage (e.g. USA with 460†V).
Adjustment range:
Resolution:
Factory setting:
When control release is active the adjustment was not completed.
"nco" appears in the display!
Date
Name: Basis
17.05.04
KEB COMBIVERT F5-M / S
CP - Parameter
0,0...700,0 A
0,1 A
LTK
U
A
0...400 Hz
100%
0,0125 Hz
50 Hz
CP.18
0Ö2
1
0
©
KEB Antriebstechnik, 2003
All Rights reserved
f
CP.19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents