Description Of In-Parameter - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Operating and Unit Data

6.1.6 Description of In-Parameter

In. 0
Inverter type
Adr.
0E00h
The inverter type is represented as hexadecimal number. The bits have following significance:
Bit 0-4
Unit size
Bit 5
Voltage class
Bit 6
Phases
Bit 7
free
Bit 8-12
Housing
Bit 13-15
Control type
Example:
In. 1
Rated inverter current
Adr.
0E01h
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.
©
KEB Antriebstechnik, 2002
All Rights reserved
min
max
0h
FFFFh
05, 07, 09 ...
0 = 230 V
1 = 400 V
0 = 1-phase
1 = 3-phase
0 = A
1 = B
2 = C
3 = D
4 = E
5 = F
6 = G
7 = H
8 = I
9 = J
0 = G
1 = M
2 = B
3 = S
4 = A
hex
0
binary
0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0
decimal
0
=>
10.F5.G 230V/1ph.
min
max
LTK
710
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
1
10 = K
20 = U
11 = L
21 = V
12 = M
22 = W
13 = N
23 = X
14 = O
24 = Y
15 = P
25 = Z
16 = Q
17 = R
18 = S
19 = T
4
0
4
0
0
10
0,1
default
hex
-
A
default
A
-
Date
Chapter
Section
6
1
12.05.04
6
Page
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents