Analog In- and Outputs
6.2.9
Selection Set
Point-/Auxiliary
Input (An.30)
©
KEB Antriebstechnik, 2002
All rights reserved
Following functions are combined in An.30:
- Bit 0..2
Selection of the analog input (AN1, AN2, AN3) as REF analog
- Bit 3..5
Mode of the AUX-Function
- Bit 6..10
Selection source 1 for the AUX-Function
- Bit 11..15 Selection source 2 for the AUX-Function
For possible expansions not all values are defined in the bit groups. Not defined values
have the same function as value 0. The sum of the respective values is to be entered.
Assignment of the analog inputs:
Function
Bit 0..2
Value
REF analog
0
AN1 (ru.28) (default)
1
AN2 (ru.30)
2
AN3 (ru.32)
Bit 3..5
Function
Value
Mode of the AUX-Function
0
Source 1 (default)
8
Source 1 + Source 2
16
Source 1 * (100% + Source 2)
24
Source1 * Source 2
32
Source1 absolute
Function
Bit 6..10
Value
Aux-input source 1
0
AN1 (ru.28)
64
AN2 (ru.30) (default)
128
Percental setpoint value (op.5)
192
Motorpoti (ru.37)
256
Process controller output (ru.52)
320
AN3 (ru.32)
Function
Bit 11..15
Value
Aux-input source 2
0
AN1 (ru.28)
2048
AN2 (ru.30) (default)
4096
Percental setpoint value (op.5)
6144
Motorpoti (ru.37)
8192
Process controller output (ru.52)
11240
AN3 (ru.32)
x: not for control card BASIC
Name: Basis
KEB COMBIVERT F5
Functional Description
Date
04.05.04
x
x
x
x
x
x
Chapter
Section
Page
2
9
6
6