Siemens Simovert Masterdrives Compendium page 505

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

03.2010
NOTE
8.4.2.4
Mounting positions of the CBC in VC Compact PLUS units
NOTE
Position of the slots
DANGER
Siemens AG
6SE7087-6QX70 (Version AL)
SIMOVERT MASTERDRIVES
On the adapter board, only one CBC may be mounted in position X
198, i.e. BOTTOM.
In order to mount the CBC with adapter board, the LBA (Local Bus
Adapter) backplane adapter must first be mounted.
If only one optional board is used, it must always be plugged in position
+1.B2 (RIGHT) in the electronics box.
If, in addition to the CBC, a technology board (T100 / T300 or T400) is
plugged into the electronics box, the technology board must be plugged
into position +1.B2. In this case, the CBC is plugged into position
+1.B3.
In principle, the optional CBC board (Communications Board CAN) can
be mounted in any slot.
SIE MENS
A
S1
X101
B
X103
Fig. 8.4-7
Position of the slots (with side wall on the right removed)
Due to the DC link capacitors, hazardous voltages are still present in
the converter up to 5 minutes after it has been disconnected from the
power supply. Before opening the converter, wait until the capacitors
have completely discharged.
Compendium Motion Control
Fastening screw for
side cover
Inscription fields for
optional boards
Fastening screw for
side cover
Communication / CBC
Slot A
Slot B
Terminal
module
8.4-7