n959.02 = 7
Src Disp Binec
P030.x
.01
B
.02
B
BIN
.03
B
.04
B
.05
B
n959.03 = 7
Src Disp Conn
P032.x
.01
KK
.02
KK
%
.03
KK
.04
KK
.05
KK
n959.04 = 7
SrcDisp DecConn
P044.x
.01
KK
.02
KK
Dez
.03
KK
.04
KK
.05
KK
n959.05 = 7
SrcDisp HexConn
P046.x
.01
KK
.02
KK
Hex
.03
KK
.04
KK
.05
KK
1
2
General functions
Free display parameters
n959.06 = 7
SrcDispAmpsConn
Display Binector
P036.x
r031.1 to 5
K
K
K
K
K
n959.07 = 7
Display Conn
Indicated in 0.001 %
r033.1 to .5
SrcDispVoltsConn
P034.x
K
K
K
K
K
Disp DecConn
r045.1 to .5
n959.08 = 7
SrcDisp TorqConn
P038.x
K
K
K
K
Disp HexConn
K
r047.1 to .10
- In r047.1 to .5, the higher word of
P046.1 to.5 is indicated.
- In r047.6 to .10, the lower word of
P046.1 to .5 is indicated.
3
4
Ref Amps
[20.5]
Disp Amps Conn
.01
Indicated in 0.01 A
.02
r037.1 to .5
A
.03
.04
.05
Ref Volts
[20.5]
Disp Volts Conn
.01
Indicated in 0.1 V
.02
r035.1 to .5
V
.03
.04
.05
Ref Torque
[20.5]
Disp Torq Conn
.01
Indicated in 0.01 Nm
.02
r039.1 to .5
Nm
.03
.04
.05
5
V2.5
fp_mc_030_e.vsd
08.01.02
n959.09 = 7
Ref Speed
[20.5]
SrcDisp SpdConn
P040.x
Disp Speed Conn
.01
KK
Indicated in 0.1 1/min
.02
1/
r041.1 to .5
KK
.03
KK
min
.04
KK
.05
KK
n959.10 = 7
Ref Frequency
[20.5]
SrcDispFreqConn
P042.x
Disp Freq Conn
.01
KK
Indicated in 0.01 Hz
.02
r043.1 to .5
KK
Hz
.03
KK
.04
KK
.05
KK
6
7
Function diagram