Siemens Simovert Masterdrives Compendium page 879

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Technology Option F01
New parameters
9.11.6
Software version V2.1
Synchronism –
generation of
position setpoint
[836]
New parameters
9-188
♦ U449
Rounding mode, catch-up
♦ n459.1,2
Display parameters, tables of X/Y axis positions
♦ U600.4-6
Master speed setpoint, master axis [%]
♦ U461.1-2
Source, additive offset, slave
♦ U607.2
Scaling speed, master
♦ U607.2
Scaling speed, slave (alternative to MD23, here with
two places after the decimal)
♦ n654.1...2
Display of set gear factor (numerator/denominator)
♦ n634
Display of free support points for the table, in
variable table configuration mode (U615=4)
♦ n639.1...16
Table information: Display parameters giving
information as to which tables are to be found in
which parameters. Beginning of table, end of table.
♦ n466.1...2
Visualization parameters for offset angle adjustment
and synchronization.
Residual offset: Index 1
Current offset: Index 2
♦ U467
Maximum correction speed in 1000LU/min,
alternative to U667 maximum correction speed in
LU/sampling time.
(delivery as of: 06.03)
Creation of a docking point between the basic positioner and the
synchronous block so as to ensure that the drive can be operated in
position control mode after the axis has been stopped via the catch-up
function.
Setpoint source U886.1 for position setpoint [LU] and U886.2 for speed
setpoint [%]
The function is activated via U885.
♦ U885
Synchronism local ON
♦ U886.1...2
Setpoint source synchronism local
6SE7087-6QX70 (Version AN)
Compendium Motion Control
08.2012
Siemens AG
SIMOVERT MASTERDRIVES

Hide quick links:

Advertisement

Table of Contents
loading