Siemens Simovert Masterdrives Compendium page 870

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

08.2012
9.11
Modification history of technology option F01
9.11.1
Software version V1.0
9.11.2
Software version V1.1
Modified parameters
New parameters
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
The specified software versions are basic unit software versions. There
are no special version numbers for technology option F01. The
following section only lists software versions in which changes have
been made to technology option F01.
(Start of Shipping: November 97)
Original version, for pilot customers only
(Start of Shipping: February 98)
V1.1 was only supplied to pilot customers.
♦ U529.01....02: These parameters have been omitted and no longer
need to be set. Basic unit connectors K030 (control word 1), K032
(status word 1) and K250 (fault/warning number) are now connected
permanently to the positioning function (see " Positioning input
signals ").
♦ U511...U520: These triple-index parameters are no longer used for
permanent MDI blocks 1...10. Instead, they are stored in
parameters U550...U559.
♦ U550...U559: Permanent MDI blocks 1...10
Compendium Motion Control
Technology Option F01
9-179