Parameterization
5.4.3
Operator control
5.4.3.1
Operator control elements
Key
ON key
OFF key
O
Jog key
Jog
Reversing key
Toggle key
P
Reset key
Reset
Raise key
Lower key
Sign key
+/-
Number keys
0
9
to
5-16
Significance
•
For energizing the drive (enabling motor activation). The
function must be enabled by P554.
•
For de-energizing the drive by means of OFF1, OFF2 or
OFF3. The function must be enabled by P554 to P560.
•
For jogging with jog setpoint 1 (only effective when the
unit is in the "Ready to start" state). This function must
be enabled by P568.
•
For reversing the direction of rotation of the drive. This
function must be enabled by P571 and P572.
•
For selecting menu levels and switching between
parameter number, parameter index and parameter
value in the sequence indicated. The current level is
displayed by the position of the cursor on the LCD
display (the command comes into effect when the key is
released).
•
For conducting a numerical input.
•
For leaving menu levels
•
If fault display is active: For acknowledging the fault. This
function must be enabled by P565
For increasing the displayed value:
•
Short press = single-step increase
•
Long press = rapid increase
•
If motorized potentiometer is active, this is for raising the
setpoint. This function must be enabled by P573
For lowering the displayed value:
•
Short press = single-step decrease
•
Long press = rapid decrease
•
If motorized potentiometer is active, this is for lowering
the setpoint. This function must be enabled by P574
•
For changing the sign so that negative values can be
entered
•
Numerical input
Table 5-9
Operator control elements of the OP1S
Function
6SE7087-6QX70 (Version AL)
Compendium Motion Control
03.2010
Siemens AG
SIMOVERT MASTERDRIVES