Siemens Simovert Masterdrives Compendium page 951

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

General visualization parameters
r001 Drive status
r002 n(act)
r004 Output Amps
r006 DC Bus Volts
r007 Motor Torque
r009 Motor Temperat.
r069 SW Version
r828 SW ID
r001 Drive Status
0:
Converter
4:
Config. boards
5:
Drive setting
7:
Fault
8:
Switch-on inhibit
9:
Ready for switching on
10: Precharging of the DC link
11: Ready
14: Operation
15: OFF 1 active
16: OFF 3 active
18: Mot ID at a standstill
21: Download
1
2
General functions
Visualization and normalization parameters
K0249
Pxxx.B => BICO data-set parameter (2 indices)
Switchover by control-word bit 30 [190.2]
KK0091
Active BICO DSet. r012
K0242
K0240
Pxxx.F => Function data-set parameter (4 indices)
Switchover by control-word bit 16/17 [190.2]
K0241
Active FuncDSet r013
Normalization variables for closed-loop and open-loop control of the unit or the equipment
P350 (~):
P351 (500):
P352 (50):
P353.01 (3000): Ref Speed
P353.02:
P354 (~):
P355:
P060 Menu Select
0: User param
Physical variable
1: Parameter menu
in A, V, Hz, 1/min
2: FixedSet. menu
3: Quick param. menu
4: Board Config.
Display parameter
5: Drive setting
6: Download
Torque in %
7: Upread/Free access
8: Power section def.
Notes:
1.
Both the limit values of the control (e.g. speed, torque, current) and normalization of the internal and
external setpoint and actual-value data are influenced.
2.
When calculation of the motor model (P115) is selected, the values are pre-assigned to motor or converter
rated quantities (only in converter state r001=5).
3.
The listed parameter values can only be changed in the "Drive setting" menu (P060 = 5).
3
4
(Function Data Set)
Ref Amps
(0.0 ... 650 A)
Ref Volts
(0 ... 5000 V)
Ref Frequency
(0 ... 500 Hz)
(0 ... 10000 1/min)
4 digits after decimal point
Reference speed
1 equiv. 0.0001 to 9999 equiv. 0.9999
Ref Torque
(0 ... 6500 Nm)
Ref Temp
256 °C
MachRefSpeed
(0 ... 10000 1/min)
Process variable with normalization
4000
(
0000
)
Hex
4000 (0000)Hex = 100 %
reference
parameter
4000Hex
P113
100%
P354
5
6
V2.5
fp_mc_020_e.vsd
01.07.03
Connectors
4000 (0000)Hex = 100 %
7
8
Function diagram
- 20 -
MASTERDRIVES MC