08.2012
Changed
parameters
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
♦ U501.08
MD8 :
♦ U501.45
1 = Start OR-gated
2 = Start AND-gated
3 = Position-feedback setting on the fly
4 = External set change
5 = Measuring on the fly
6 = Collision
7 = Bero for homing
8 = Reversing cam for homing
9 = Release read-in, dependent on external
program
♦ U627.3,.4
Parameter Index 3 and 4 do not apply (not used)
♦ U628.3,.4
Parameter Index 3 and 4 extended
Acceleration/deceleration for positioning
♦ n655.1...5
Position display parameter [LU] for synchronism
extended
♦ n653.1..5
Speed display parameter [%] for synchronism
extended
♦ n668.1...8
Status of tables extended to Tables 1-8
♦ U602
Synchronism mode extended from 0..2 to 0..3
(catch-up)
♦ U615
Table configuration extended from 1,2 to 0...4 for 8
tables
♦ U650.1..3
Binector for table selection extended for 8 tables.
Compendium Motion Control
Technology Option F01