Siemens Simovert Masterdrives Compendium page 360

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Communication / PROFIBUS
8.2.4.3
Example of "Change parameter value", simple
8.2-30
Parameter task:
Task header
Task reference
Axis = 0
Parameter
Attribute = value
address
Parameter number
Subindex = 0
Parameter value
Format = word
Value
Positive parameter response:
Response header
Task ref. mirrored
Axis mirrored
Negative parameter response:
Response header
Task ref. mirrored
Axis mirrored
Parameter value
Format = error
Error value
Task identifier =
Change parameter
No. of parameters = 1
No. of elements = 0 (!)
No. of values = 1
Response identifier =
Change parameter (+)
No. of parameters = 1
Response identifier =
Change parameter (-)
No. of parameters = 1
No. of values = 1
6SE7087-6QX70 (Version AK)
Compendium Motion Control
09.2008
Offset
10
12
14
0
2
4
0
2
4
6
8
Siemens AG
SIMOVERT MASTERDRIVES
0
2
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents