Siemens Simovert Masterdrives Compendium page 330

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

02.2004
Example 2
Parameter
Parameter
number
SCB actual
P706
values
NOTE
Siemens AG
6SE7087-6QX70 (Version AD)
SIMOVERT MASTERDRIVES
"Interconnection" of status word 1, status word 2, actual speed
(KK0091) and the actual DC link voltage (K0240) at the interface on
SCB2.
♦ Precondition:
PZD area at least 5 words in length; P703, i003 ≥ 5 is set.
Index and value
i001 = 0032
i002 = 0091
i003 = 0091
i004 = 0033
i005 = 0240
When 32-bit quantities are being transferred, the high word is located in
PZD n, the low word in PZD n+1.
→ For example, 32-bit actual value of KK0091 in PZD2 and PZD3.
Compendium Motion Control
Comments
1st word in the PZD area:
status word (K0032)
2nd word in the PZD area:
high word of the actual speed (KK0091)
3rd word in the PZD area:
low word of the actual speed (KK0091)
4th word in the PZD area:
status word 2 (K0033)
5th word in the PZD area:
Vd(act) (K0240)