Encoder types
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
Possible baud rate depending on the cable length:
2000
1500
1000
500
2
4
6
Setting for P149.01 and P149.07
xxx3x
Fig. 9-11
Possible baud rate depending on the cable length
The EQN1325, ECN1313 and EQI1325 encoders require a
6FX_002-2EQ10-____ connecting cable.
Not all measuring system manufacturers support baud rates up to
2 Mbaud. The serial protocol for the motor encoder is only required for
initialization and redundancy monitoring. These functions are non-time-
critical. A baud rate of 100 kHz (standard setting) is recommended for
immunity to interference.
Only encoders which generate incremental tracks, in addition to
transmitting the position using the serial protocol, are suitable as motor
encoders. The sensor board supports the serial SSI and EnDat
protocols.
Recommended coded rotary encoders:
Name
Res./ Rev.
EQN 1325
ECN1 313
EQI 1325
Compendium Motion Control
20
60 80
8 10
xxx2x
Coded Rotary Encoder
Rev.
8192
4096
8192
-
256
4096
Technology Option F01
100
150
Cable length/m
xxx1x
xxx0x
Protocol
Multiturn
EnDat
Standard
EnDat
Singleturn
EnDat
Multiturn
9-23