Siemens Simovert Masterdrives Compendium page 335

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

09.2008
8.2.2.1
Cyclical data transmission
DANGER
The structure of
useful data as PPOs
Siemens AG
6SE7087-6QX70 (Version AK)
SIMOVERT MASTERDRIVES
The following illustration contains an overview of the communications
functions which are enabled with the CBP2:
Automation
(Master class 1)
S7, S5 and other
Cross traffic
(slave)
Drive, ET200
Drive, ET200
Fig. 8.2-4
Data-traffic channels of the CBP2
When interconnecting connectors, binectors, and double word
connectors, please note that simultaneous interconnection of a
connector, and a double word connector with the same name is not
permitted, because when a double word connector (e. g. KK3032) is
connected, the meanings of the connectors K3002 and K3003 are
swapped round (high-word and low-word exchanged).
On MASTERDRIVES MC and Compact Plus on software version V1.50
and higher and on MASTERDRIVES CUVC on software version V3.23
and higher, simultaneous use of connectors and double word connectors
with the same name is mutually interlocked (see also function diagrams
[121] and [131]).
Because the binectors are not included in the interlocking (to ensure
compatibility for older configurations), their significance changes
according to whether the pertinent word or double word is wired.
Useful data for the cyclical MSCY_C1 channel (see Figs. 8.2-3 and 8.2-
4) is structurally defined in the PROFIBUS profile for variable-speed
drives version 2 as a parameter process data object (PPO).
Frequently, the cyclical MSCY_C1 channel is simply called the
STANDARD channel as well.
Compendium Motion Control
Communication / PROFIBUS
Configuration
Operational control
(Master class 2)
DriveES, DriveMonitor
Cyclical channels
Acyclical channels
MASTERDRIVES - CU
(Master class 2)
SIMATIC OP
CBP2
8.2-5