Siemens Simovert Masterdrives Compendium page 214

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

09.2008
DANGER
Siemens AG
6SE7087-6QX70 (Version AK)
SIMOVERT MASTERDRIVES
The following assignment applies regarding the parameterization of
time slots in parameters U950 to U953:
Time slot
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T20
Examples:
1. Function block 350 should be processed in time slot T4:
U953.50 = 4
2. Function block 390 should be processed in time slot T9:
U953.90 = 9
3. Function block 374 should not be processed:
U953.74 = 20
When the units are delivered, time slots are already assigned to the
function blocks. You should adjust these to suit your requirements once
you have determined the interconnection of the function blocks.
Please note that an incorrect processing sequence will lead to
uncontrolled axis movements!
Compendium Motion Control
Parameter value
-
-
2
3
4
5
6
7
8
9
10
20