03.2010
Key
Significance
Toggle key
Raise key
Lower key
Hold toggle key
and depress raise
key
Hold toggle key
and depress lower
key
PMU in units of the
Compact and
chassis type
Raise key
Reversing key
ON key
Toggle key
OFF key
Lower key
Siemens AG
6SE7087-6QX70 (Version AL)
SIMOVERT MASTERDRIVES
•
For switching between parameter number, parameter index
and parameter value in the indicated sequence (command
becomes effective when the key is released)
•
If fault display is active: For acknowledging the fault
For increasing the displayed value:
•
Short press = single-step increase
•
Long press = rapid increase
For lowering the displayed value:
•
Short press = single-step decrease
•
Long press = rapid decrease
•
If parameter number level is active: For jumping back and forth
between the last selected parameter number and the
operating display (r000)
•
If fault display is active: For switching over to parameter
number level
•
If parameter value level is active: For shifting the displayed
value one digit to the right if parameter value cannot be
displayed with 4 figures (left-hand figure flashes if there are
any further invisible figures to the left)
•
If parameter number level is active: For jumping directly to
operating display (r000)
•
If parameter value level is active: For shifting the displayed
value one digit to the left if the parameter value cannot be
displayed with 4 figures (right-hand figure flashes if there are
any further invisible figures to the right)
Table 5-6
Operator control elements of the PMU (Compact PLUS type)
Seven-segment display for:
Drive statuses
Alarms and
faults
Parameter numbers
Parameter indices
X300
Parameter values
Fig. 5-3
PMU parameterizing unit
Compendium Motion Control
Parameterization
Function
5-7