Siemens Simovert Masterdrives Compendium page 876

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

08.2012
9.11.5
Software version V1.4
General
synchronism
Real master [833]
Electronic cam [839]
Additive offset
New free blocks
[794]
Speed input [834]
Visualization
parameters
Position correction
[843]
Start/Stop [834]
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
(Start of delivery: 12.99)
Concerning the Synchronism function, please note that the smallest
permissible time slot is T4 ( P2953.33 = 4 ).
The "Real Master" function block is no longer part of Technology Option
F01, but is a free block.
Set the setting value. This is only effective for the output. Additional
connector KK624 as speed output in %.
The electronic cam has been extended from 2 to 8 tables and from 200
to 400 support points.
The assignments X101-X150 = U640; Y101-Y150 = U645;
X151-X200 = U641; Y151-Y200 = U646; X201-X250 = U632;
Y201-Y250 = U637; X251-X300 = U633; Y251-Y300 = U638.
Amendment to the configuration table (U615):
0 = 1 table with 400 support points; 1 = 2 table with 200 support points
each;
2 =4 tables each with 100 support points; 3 = 8 tables each with
50 support points;
4 = max. 8 tables with a total of 400 support points.
New status binector: Stop at table end B834
Supplementary in the case of synchronism: external position setpoint
setting possibility (U460 and U461])
To be used herewith:
Free block 'Additive offset adjustment analogous to offset angle
adjustment in synchronism, only external
'Offset adder with limitation' for modulo calculation of position setpoints.
Supplementary in the case of synchronism: Speed input in percent [%]
(U600. 4 to 6), analog switchable with the position sources from the
master setpoint source.
Supplementary in the case of synchronism: Visualization parameters
n655 for position setpoint [LU], n653 for speed [%], n654 for gear
factor, n466 for offset angle
Supplementary in the case of synchronism position correction:
Parameter U467 for input of the setting speed in [1000LU/Min]
Supplementary in the case of synchronism: Status binectors start/stop
(B831, B832; B833)
Compendium Motion Control
Technology Option F01
9-185

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents