Siemens Simovert Masterdrives Compendium page 856

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

08.2012
9.8.14
Connecting the technology to the speed and position controller
; Connecting the technology to the position and speed controllers
P210.1=1, P211=1
P220.1=131
P194.1=120
(WE)
or
P194.1=125
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
If you only use the synchronization function, you only need to modify
the following machine data (see also the "Synchronization mode -
overview" section in "Brief description of the technology functions"):
Machine Data Overview for Synchronization
Synchronization as
Positioning Mode
Relevant machine
MD11
data
MD49
MD12 *) Software limit
MD13 *) ... for linear axis
MD15 *) Following error
MD23
Commissioning step:
Connect the technology to the speed and position controllers:
[817] shows the setpoint outputs for the position controller and speed
controller in addition to the enabling of the position controller by the
technology. These connections are established to a large extent in the
factory settings. Only the parameters below need to be modified (see
the section entitled "Connecting the technology to the speed and
position controllers" in application example 2):
; Enable 1 and 2 for position controller
; permanently set to "1" [340.1]
; Wire position controller output to
; speed controller [340.8] ==> [360.1]
; Connect actual pos. from motor
; encoder [330] to actual value input [340.1] of
; position controller ...
; ... or actual position of external machine
; encoder, if one is used.
Compendium Motion Control
Synchronization as Free
Block
MD11
[836.4]
MD49
switches ...
monitoring - in
motion
MD23
Technology Option F01
Linear axis/rotary
axis length
Weighting of
velocity
precontrol [836.7]
9-165