Position sensing
Configuration of position sensing for motor encoder in slot C
P183
Configuration of position sensing
Position of
Value
Meaning
P183.01
Encoder sensing
xxx0
- No position sensing with motor encoder in
slot C
xxx1
- Release position sensing with resolver
or encoder
xxx2
- Release position sensing with multiturn
encoder
Reference point detection mode
xx0x
- No reference point detection
xx1x
- At the right of the rough pulse
The first rotor zero position at the right of
the rough pulse sets position sensing to
the setting value
xx2x
- The first rotor zero position at the left of
rough pulse sets position sensing to the
setting value
x0xx
- Counting direction the same as direction
of motor rotation
x1xx
- Counting direction opposite to direction
of motor rotation
0xxx
- Input of position feedback scaling factor
with components left and right of decimal
1xxx
- Input of position feedback scaling factor
as numerator/denominator
P183.02
xxx0
- Zero offset encoder
Zero offset correction OFF
xxx1
- Zero offset correction ON
xx0x
- Reference point detection
Set position to setting value
xx1x
- Reference point detection
Only measure position