Siemens Simovert Masterdrives Compendium page 882

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

08.2012
9.11.9
Software status V2.4
Basic positioner
Register decoupling
New parameters
Extended
parameters
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
Static STOP cam (see Section 7.2.3 and FD789a)
Two new free blocks (register displacement and register decoupling),
see function diagram 842.
♦ U700
Connector parameter
• U700.1 Adaptation of circumference
• U700.2 Decoupling from predecessor
• U700.3 Setting value
• U700.4 Register displacement offset angle
• U700.5 Register displacement offset angle speed
• U700.6 Decoupling
• U700.7 Adjustment speed of printing cylinder
• U700.8 Current angular speed of printing cylinder
• U700.9 Current circumference
♦ U701
Binector parameter
• U701.1 Enable register displacement
• U701.2 Set register displacement
• U701.3 Enable register decoupling
♦ U702
Function parameter - Adaptation
• U702.1 Speed adaptation register displacement
• U702.2 Speed adaptation register decoupling
• U702.3 T constant adaptation register decoupling
♦ U703
Function parameter - General parameters
• U703.1 Register displacement axis cycle
• U703.2 Circumference
• U703.3 Normalization of circumference
• U703.4 Distance printing position
♦ U704
Function parameter - Normalization
• U704.1 Normalization of speed
• U704.2 Normalization of web speed
♦ U705
Selection parameter
• U705.1 Operating mode
• U705.2 Characteristic
♦ U887
BPos Mode Cam
0 = Edge change
1 = Static
♦ n465
Visualization paramater
• n465.2
Current adjusting speed including v_inching
as a percentage referred to U607
Compendium Motion Control
Technology Option F01
9-191

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents