Siemens Simovert Masterdrives Compendium page 946

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Engineering Information
Overview
75
90
110
132
160
200
200
250
250
11-46
Basic unit with F02 as additional
option
90
186
254
221
110
210
287
250
132
260
355
309
160
315
430
375
200
370
503
440
250
510
694
607
510
694
607
250
315
590
802
702
315
590
802
702
*400
690
938
821
*400
690
938
821
*500
860 1170
1023
*630 1100 1496
1310
*710 1300 1768
1547
* Performance extension: Only operable with P357 = 1 (max. 2.7 kHz)
Table 11-2
Overview of units which can be operated with F02 as an additional option
205 6SE7031–8EF70
231 6SE7032–1EG70
286 6SE7032–6EG70
346 6SE7033–2EG70
407 6SE7033–7EG70
561 6SE7035–1EK70
649 6SE7036–0EK70
759 6SE7037–0EK70
6SE7087-6QX70 (Version AE)
Compendium Motion Control
06.2005
6SE7031–8TF70 2.17
1.7 75
6SE7032–1TG70 2.68 2.18 160
6SE7032–6TG70 3.40 2.75 160
6SE7033–2TG70 4.30 3.47 180
6SE7033–7TG70 5.05 4.05 180
6SE7035–1TJ70
5.8 350
– 7.10
6SE7036–0TJ70
6.6 350
– 8.20
6SE7037–0TJ70
8,8 350
– 10.20
6SE7038–6TK70
– 11.9 520
6SE7041–1TK70
– 13.4 520
6SE7041–3TL70
– 14.5 625
(F02 as add. option is included)
Siemens AG
SIMOVERT MASTERDRIVES
– 400
– 400
– 400

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents