Siemens Simovert Masterdrives Compendium page 722

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

08.2012
NOTE
WARNING
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
By how many increments must the absolute position be corrected?
Delta = 27962026 inc - 10 rev
How many revolutions does that represent and what is the remainder?
27880106
Delta_ rev =
8192
Delta_ rem = (27880106 inc - 8192
Set Zero Offset
Revolutions P146.1
The setting is added on allowing for the overflows of the representable
value range. The value range is between "zero" and the maximum
encoder resolution even after a zero offset is set.
When EnDat encoders are used, the zero offset can be transferred
from parameter P146.1 into the encoder EEPROM.
Save Zero Offset in Encoder EEPROM
Par.
Setting
P60
5
P149.2
B25
P60
1
The offset setting in P146.1 is cleared and stored on the encoder. It is
important that the correct number of lines is specified in P148.1 → if
you do not use a default encoder, we recommend that you call up the
EnDat self-startup function before saving the zero offset (P149.2 xAxx
and P149.1 xxx1)
If you store an offset in the encoder while an incorrect number of pulses
per revolution is being entered in P148.1 the motor encoder will
become incorrectly oriented and the motor may overspeed.
The fine offset within one revolution can be set with parameter P184
[330.7]. If the technology is used, the fine offset must be defined in
machine data MD10 [815.4].
Compendium Motion Control
inc
×
8192
= 27880106 inc
rev
rev = 3403 rev
inc
×
Delta_ rev) = 2730 inc
rev
-3403
Description
Switch to drive settings
Save zero offset on encoder
Return to ready for operation
Technology Option F01
9-31