03.2010
8.4.2.2
Mounting positions of the CBC in Compact and chassis units of function
classes MC (CUPM, CUMC) and VC (CUVC)
Slots
NOTE
Position of the slots
Siemens AG
6SE7087-6QX70 (Version AL)
SIMOVERT MASTERDRIVES
In the electronics box of the compact-type and chassis-type converters
and inverters, there are up to six slots available for installing an optional
board. The slots are marked with the letters A to G. Slot B is not
present in these types of unit; it is used in Compact PLUS units.
If you wish to use Slots D to G, you must first mount the LBA (Local
Bus Adapter) and the corresponding adapter board (6SX7010-0KA00).
In principle, you can operate the optional CBC board (Communication
Board CAN) in any slot. Please bear in mind, however, that an encoder
board always needs Slot C and that the LBA requires the slots to be
used in a particular sequence.
The CBC can be mounted on the adapter board in both slots, i.e. TOP
and/or BOTTOM.
The slots are located at the following positions:
♦ Slot A
CU board
♦ Slot C
CU board
♦ Slot D
Adaptation board in mount. pos. 2
♦ Slot E
Adaptation board in mount. pos. 2
♦ Slot F
Adaptation board in mount. pos. 3
♦ Slot G
Adaptation board in mount. pos. 3
Adaption board
Fig. 8.4-5
Adaptation board with optional boards and position of the slots for
Compact units and chassis-type units
Compendium Motion Control
Electronics box
top
Optional board
bottom
Communication / CBC
Top
Bottom
Top
Bottom
Top
Bottom
Mounting pos. 1
Mounting pos. 3
Mounting pos. 2
8.4-5