Siemens Simovert Masterdrives Compendium page 933

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

06.2005
Siemens AG
6SE7087-6QX70 (Version AE)
SIMOVERT MASTERDRIVES
P
Mot
7.09 kW
0.734 kW
1 s
0.25 s
-4.53 kW
Fig. 11-17
Characteristic of the motor output for forwards travel
♦ The maximum DC link current during operation of the motor during
acceleration is
=
I
Link Inv
max
η
Mot
7090
=
0 92 0 98 135 400
.
.
.
♦ The mean motor power output during operation of the motor is
calculated from the positive characteristic of the motor power output
as follows:
P
Mot A
=
P
Mot mean
1
+
7 09 0 25 0 734 1
.
.
.
2
=
3 5
.
♦ The mean value of the DC link current is therefore:
P
=
I
Link mean
η
η
Mot
463
=
0 92 0 98 135 400
.
.
.
Compendium Motion Control
0.25 s
Negative area corresponds to regenerative
operation
3.5 s
P
Mot
max
η
135
.
U
Inv
line
=
14 56
.
A
+
P
Mot E
t
i
2
'
T
=
0 463
.
kW
Mot mean
135
.
U
Inv
Line
=
0 95
.
A