Parameterizing Steps
6.3
Quick parameterization procedures
6.3.1
Parameterizing with user settings
NOTE
P060 = 2
P366 = ?
P970 = 0
Unit carries out parameter
reset and then leaves the
"Fixed settings" menu.
6-24
The following quick procedures are always used in cases where the
application conditions of the units are exactly known and no tests and
related extensive parameter corrections are required. Typical examples
of applications for quick parameterization are when units are installed in
standard machines or when a unit needs replacing.
During parameterization by selecting user-specific fixed settings, the
parameters of the unit are described with values that are permanently
stored in the software. In this manner, it is possible to carry out the
complete parameterization of the units in one step just by setting a few
parameters.
The user-specific fixed settings are not contained in the standard
firmware; they have to be compiled specifically for the customer.
If you are interested in the provision and implementation of fixed
settings tailored to your own requirements, please get in contact with
your nearest SIEMENS branch office.
Select "Fixed settings" menu
Select desired user setting
0:
Factory settings
1...3: (Not implemented at present)
4:
User setting 1
5:
User setting 2
...
Start parameter reset
0: Parameter reset
1: No parameter change
Fig. 6-4
Sequence for parameterizing with user settings
6SE7087-6QX70 (Version AN)