Analog input
-10 V ... 10 V = -100.0 % ... 100.0 %
+
-X101/9
+/- 10 V
-X101/10
Hardware smoothing
10 s
Analog output
AnaOut Conf
0 ... 3
P641.F (0)
Src AnaOut
-1
3
P640.B (0)
-1
K
2
1
0
1
2
MC terminals
Analog inputs/outputs
AnaIn Offset
-100.00 ... 100.00 %
P631 (0.00)
AnaIn Scale
0.00 ... 100.00
P630 (1.00)
11 bits + sign
A
+
+
D
AnaIn NL value
K0010
AnaOut Smooth
AnaOutScale
0 ... 100 ms
-200 ... 200 V
P642.F (0)
P643.F (10.0)
[ ]
x
x
y V =
P643
100 %
AnaOut ActV
K0015
3
4
Src AnaIn Invert
AnaIn Conf
P633 (0)
0 ... 3
B
P632 (0)
-1
3
0
-1
2
-1
1
1
0
AA Offset
-10.0 ... 10.0 V
P644.F (0.0)
8 bits + sign
D
+
y
+
A
Hardware smoothing
2 ms
5
V2.5
fp_mc_080_e.vsd
Src AnaIn Rel
P636 (1)
B
AnaIn Smooth
AnaIn Window
0.0 ... 100.0 ms
0.0 ... 100.0 %
P634 (0.0)
P635 (0.0)
0 %
0
y=x if
x
y
ly-xl > P635
y=y(old)
1
otherwise
-X101/11 AA
-X101/12 M
6
7
Function diagram
MASTERDRIVES MC
02.02.04
n959.17 = 2
AnaIn Setp
r637
AnaIn Setp
K011
n959.18 = 4
8