Siemens Simovert Masterdrives Compendium page 81

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

12.2010
Parameter
Channel 1
Safety relay –K1
B10
value
d
nop
MTTF
(-K1)
d
Interim result channel 1
MTTF
(channel1)
d
Channel 2
Line contactor –K2
B10
value
d
nop
MTTF
(-K2)
d
Interim result
Channel 2
MTTF
(channel2)
d
Interim results for REACT (channels 1 and 2)
MTTF
(REACT)
d
Siemens AG
6SE7087-6QX70 (Version AM)
SIMOVERT MASTERDRIVES
♦ Determination of MTTF
Value
20.000.000
24972 per year
8008 years
8008 years
Capped to 100 years
1.333.333
12 per year
1,111,111 years
1,111,111 years
Capped to 100 years
100 years
→ High
Compendium Motion Control
Configuration and Connection Examples
value
d
Comment
Specified by manufacturer
24960 per year due to protective door
+ 12 per year due to Emergency Stop
B
10
d
=
MTTF
d
0
1 ,
×
n
op
Specified by manufacturer
12 actuations per year due to Emergency Stop
B
10
d
MTTF
=
d
×
0
1 ,
n
op
MTTF
values of both channels have been
d
capped to 100 years →
It is not necessary to symmetrize both
channels.
2-53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents