MP3300 Installation and Usage Conditions

Install the MP3300 Controller in an environment with the following conditions.
A.2.1
Environmental Conditions
Item
Ambient Operating Temperature
Ambient Storage Temperature
Ambient Operating Humidity
Ambient Storage Humidity
Pollution Degree
Corrosive Gas
Operating Altitude
Control Panel Cooling Method
The components that are used in the MP3300 require the ambient operating temperature to be
between 0 and 60°C. Use one of the methods described below to ensure adequate cooling in
the control panel.
If the ambient temperature exceeds 55°C, use forced-air cooling.
Note
 Control Panels with Natural Cooling
• Do not mount the MP3300 at the top of the control panel, where the hot air that is generated
inside the panel collects.
• Leave sufficient space above and below the MP3300, and maintain adequate distances from
other devices, cable ducts, and other objects to ensure suitable air circulation.
• Do not mount the Machine Controller in any direction other than the specified direction.
• Do not mount the Machine Controller on top of any device that generates a significant
amount of heat.
• Do not subject the Machine Controller to direct sunlight.
Specification
0 to 60°C (Forced cooling is required if 55°C is exceeded.)
−25 to 85°C
10% to 95% RH (with no condensation)
10% to 95% RH (with no condensation)
Conforms to JIS B 3502 Pollution Degree 2.
There must be no combustible or corrosive gases.
2,000 m max.