Emc Installation Conditions - YASKAWA SGD7S Product Manual

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

3.7 EMC Installation Conditions

3.7

EMC Installation Conditions

This section gives the installation conditions that were used for EMC certification testing.
The EMC installation conditions that are given here are the conditions that were used to pass
testing criteria at Yaskawa. The EMC level may change under other conditions, such as the
actual installation structure and wiring conditions. These Yaskawa products are designed to be
built into equipment. Therefore, you must implement EMC measures and confirm compliance
for the final equipment.
The applicable standards are EN 55011 group 1 class A, EN 61000-6-2, EN 61000-6-4, and
EN 61800-3 (category C2, second environment).
• Three-Phase, 200 VAC
Power supply:
Three-phase, 200 VAC
Host controller
(DeviceNet master)
Note: 1T: 1 turn
2T: 2 turns
Symbol
3-8
Noise
Filter
Surge
Absorber
Regenerative
Resistor Unit
PE
1T
Cable Name
I/O Signal Cable
Safety Function Device Cable
Servomotor Main Circuit Cable
Encoder Cable
Main Circuit Power Cable
DeviceNet Communications Cable
Shield box
Brake power supply
SERVOPACK
U, V, W
L1, L2, L3
L1C, L2C
CN2
B1, B2
CN1
CN8
Clamp
I/O
controller
Specification
Shielded cable
Shielded cable
Shielded cable
Shielded cable
Shielded cable
Shielded cable
Brake
Servomotor
Encoder
PE
Safety function
device