YASKAWA MP3000 Series Setup Manual page 310

Machine controller system
Hide thumbs Also See for MP3000 Series:
Table of Contents

Advertisement

B.2 Setting Parameters
Register
Address
OW08
(Continued
from previous
page.)
OW09
B-8
Name
24: TRQ (Issue Torque/Force Reference)
(Torque/Thrust reference)
25: PHASE (Issue Phase Reference) (Phase
reference)
26: KIS (Change Position Loop Integral Time
Constant)
27: PPRM_WR (Write Non-volatile Parame-
ter) (Stored parameter write)
Motion Com-
mands
28 to 33: Reserved for system.
34: EX_FEED (Jog with External Positioning)
(Jog mode with external positioning)
35: MEM_RD (Read Memory)
36: MEM_WR (Write Memory)
37: PMEM_RD (Read Non-volatile Memory)
38: PMEM_WR (Write Non-volatile Memory)
Bit 0: Hold Command (Holds a command)
0: OFF, 1: ON
Bit 1: Cancel Command (Interrupt a com-
mand)
0: OFF, 1: ON
Bit 2: Travel Direction
(Moving direction (JOG/STEP))
0: Forward, 1: Reverse
Bit 3: Zero Point Return Direction Selection
0: Reverse, 1: Forward
Bit 4: Latch Zone Enable (Latch zone effec-
tive selection)
0: Disabled, 1: Enabled
Bit 5: Position Reference Type
Motion Com-
0: Incremental value addition method (Incre-
mand Control
mental value add method)
Flags
1: Absolute value specification method
(Absolute value set method)
Bit 6: Electric Cam Phase Compensation
Type (Phase Compensation Type)
0: Incremental value addition method (Incre-
mental value add method)
1: Absolute value specification method
(Absolute value set method)
Bit 7: Reserved for system.
Bit 8: SERVOPACK Parameter Access
Selection (Access target servo driver user
constant)
0: Vendor-specific parameters
1: Common parameters
Bits 9 to F: Reserved for system.
Continued from previous page.
Description
SVC or
SVR or
SVB
SVC32
SVR32
Continued on next page.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp3200Mp3300