DUPINT (Duplication Interface Circuit Pack)

DUPINT (Duplication Interface Circuit
Pack)
MO Name (in
Alarm Log)
DUPINT
DUPINT
1
Alarms on Duplication Interface circuit pack in the A carrier are always major alarms and
alarms on Duplication Interface circuit pack in the B carrier are always warning alarms.
Determine the carrier to test from the
In High or Critical Reliability PPN systems, there are two Duplication Interface
(DUPINT) circuit packs: one in carrier A and one in carrier B. Together, both circuit
packs provide memory shadowing (see "SHDW-CIR" for a full description) and
communication between software on the Active and Standby SPEs. By itself,
Duplication Interface circuit pack A provides control of the duplicated Processor
circuit pack, environmental maintenance monitoring and control, and
administration terminal connection.
TN792 circuit pack
Upgrade compatibility
The TN792 Duplication Interface circuit pack is not backward compatible (only
works with system running Release 7 or greater software) because it provides
enhanced duplication by using the Enhanced M-Bus (EM-Bus) functionality in the
TN2404/TN790 processor circuit pack. The EM-Bus provides 32-bit address and
data access to improve shadowing speed and increase the shadowed memory
range. This means that:
The TN792 can replace the TN772 Duplication Interface pack, however it is
not compatible with TN772. If one Duplication Interface circuit pack is
upgraded from TN772 to TN792, then you must upgrade the other side.
The TN792 is compatible only with the TN2404/TN790 processor circuit
pack that must be upgraded simultaneously with the DUPINT circuit packs.
Existing cables are compatible with the TN792 circuit pack.
When swapping TN772s for TN792s, power down both the active and
standby carriers, swap the circuit packs, and reapply power to the carriers.
Faceplate connections
An optical cable interface connects on the front faceplate of the TN792 to shadow
data between Duplication Interface circuit packs.
555-233-123
Alarm
Initial Command
Level
to Run
MAJOR
test duplication 1C
WARNING
test duplication 1C
Port
1
Full Name of MO
Duplication Interface Circuit Pack
Duplication Interface Circuit Pack
field in the Alarm or Error Log.
Issue 4 May 2002
10-701