Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-259. Duplication Interface Circuit Pack Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1
Sanity Circuit Test (#273)
108 (a)
Any
None
109 (a)
Any
None
257
SAT Loop Back Test (#274)
513
SPE A Loop Back Test (#275)
769
SPE B Loop Back Test (#276)
1025
Sanity Maze Test (#277)
1281 (b)
Any
DUPINT Status Query Test
(#315)
1537 (c)
Any
Background Test Query Test
(#271)
1793 (d)
Any
MBUS Time-Out Query Test
(#285)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This error indicates that an unexpected hardware reset has occurred on
the Duplication Interface circuit pack. Appropriate action has been taken by
the software to prevent malfunction. However, if this type error occurs with
regular frequency, the DUPINT circuit pack may need to be replaced.
b. There are several possible Aux Data fields for this error, including blank. All
indicate loss of contact with the indicated Duplication Interface circuit
packs.
10-706
Issue 4 May 2002
Associated Test
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test dup 1C sh r 1
MAJOR/
ON
test dup 1C l r 1
WRN
MAJOR/
ON
test dup 1C sh r 3
WRN
MAJOR/
ON
test dup 1C sh r 3
WRN
MAJOR/
ON
test dup 1C sh r 3
WRN
MAJOR
ON
test dup 1C sh r 3
/WRN
MAJOR/
ON
test dup 1C sh r 6
WRN
MAJOR/
ON
test dup 1C sh r 3
WRN
MAJOR/
ON
test dup 1C l r 3
WRN