ISDN-SGR (ISDN-PRI Signaling Group)
Table 10-350. TEST #636 Primary Signaling Link Hardware Check
Error
Code
1700
4
8
555-233-123
Test
Result
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Rollabout video abort. The PRI terminal adapter associated
with this D-channel port is detached from the circuit pack. This
is a normal abort when the rollabout video feature is enabled.
To complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter and
retry test command, or
2. Disable the rollabout video feature on this circuit pack by
entering change ds1 PCSS and set the field "Alarm
when PRI Endpoint Detached?" to "y".
FAIL
There is a problem with the Processor Interface Link. No DS1
ISDN Trunk (B-channel) or wideband PRI Endpoint calls can
be made until the problem is resolved.
1. Display the Communication-Interface Links Form via the
to determine which link is down (find the one that matches
the DS1 interface circuit pack this ISDN-PRI Signaling
Link Port is on) and then consult the procedures for
Processor Interface Link.
FAIL
There is a problem with the DS1/UDS1 Circuit Pack, or the
ISDN-PRI Signaling Channel (D-channel). No DS1 ISDN
Trunk (B-channel) or wideband PRI Endpoint calls can be
made until the problem is resolved.
1. Consult the procedures for DS1/UDS1 Circuit Pack and
the ISDN-PRI Signaling Channel (ISDN-LNK/ISDN-PLK).
PASS
The basic physical connectivity of the primary D-channel is
intact and functional. Try this test repeatedly to ensure the link
is up and to uncover any transitory problems.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-969