H323-Stn (H.323 Ip Station) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Object Repair Procedures

H323-STN (H.323 IP Station)

MO Name (in
Alarm Log)
H323-STN
This maintenance object covers implementation of the maintenance for native
mode H.323 endpoints. Native mode H.323 applications such as NetMeeting or
Proshare only provide what is needed to support the H.323 standard. There is
very little that DEFINITY can invoke in the maintenance area. DEFINITY will
report errors as they are detected via the RAS registration and keep-alive
mechanism. DEFINITY will PING the endpoint both via the signaling path (i.e. via
C-LAN) and via the media path (i.e. via Medpro).
This station type is not attached to a port board. Insertion of the station is not
driven by board insertion, rather it is driven by successful registration of the
endpoint. It is maintained via a set of explicit TCP/IP ping requests and errors
reported by the switch software, which terminates the H.323 signaling portion of
each endpoint. The MO follows standard maintenance methodology and supports
test, busyout, release and status commands.
Error Log Entries and Test to Clear Values
Table 10-318. H323-STN IP Station Error Log Entries
Error
Aux
Type
Data
0
0
Any
1 (a)
Registration Status Inquiry
Test (#1372)
257 (b)
Signaling Path PING Test
(#1373)
513(c)
Media Path PING Test
(#1374)
Notes:
a. Error Type 1: this error reports the registration status of the endpoint. If call
processing SW claims the endpoint is registered and receives keep-alive
handshakes from the endpoint, the test passes. If keep-alive handshaking
has failed, the test fails. If the user has intentionally un-registered from
DEFINITY, the station is now basically an AWOH station and is no longer
being maintained; no tests will run for this station.
10-880
Issue 4 May 2002
Initial Command to
Alarm Level
WARNING
test station extension
Associated Test
Any
WARNING
WARNING
WARNING
Run
Full Name of MO
H.323 IP Station
Alarm
On/Off
Level
Board
Test to Clear Value
test station extension
OFF
OFF
OFF
555-233-123