Avaya Definity SI Maintenance Manual page 1760

Table of Contents

Advertisement

Maintenance Object Repair Procedures
P a c k e t
C o n t r o l
P r o c e s s o r
( T N 7 8 6 )
C i r c u i t
P a c k
( T N 7 7 8 )
* T N 4 6 4 C o r l a t e r
Figure 10-56. Secondary Signaling Link Hardware Check for PRI over PACCON
(Test #639)
Table 10-352. TEST #639 Secondary Signaling Link Hardware Check
Error
Code
1132
4
8
10-974
Issue 4 May 2002
P a c k e t B u s
Test
Result
ABORT
Internal system error
1. Retry the command at 1minute intervals a maximum of 5
times.
ABORT
The Secondary D-channel is not administered for this
Signaling Group. This is a NORMAL ABORT. Only a Primary
D-channel must be administered for a Signaling Group.
FAIL
There is a problem with the Processor Interface Link. No DS1
ISDN Trunk (B-channel) or Wideband PRI Endpoint calls can
be made until the problem is resolved.
1. Display the Communication-Interface Links Form via
display communication-interface to determine which
link is down (find the one that matches the DS1 Interface
circuit pack on which this ISDN-PRI Signaling Link Port
resides) and then refer to the PI-LINK Processor Interface
Link Maintenance documentation.
FAIL
There is a problem with the DS1/UDS1 Interface circuit pack
or the ISDN-PRI Secondary Signaling channel (D-channel).
No ISDN Trunk (B-channel) or Wideband PRI Endpoint calls
can be made until the problem is resolved.
1. Refer to the DS1/UDS1 circuit pack and the ISDN-PRI
Signaling channel (ISDN-LNK/ISDN-PLK) Maintenance
documentation.
PASS
The basic physical connectivity of the Signaling Group's
Secondary D-channel is intact and functional. Try this test
repeatedly to ensure the link is up and to uncover any
transitory problems.
U D S 1
I n t e r f a c e
C i r c u i t
P a c k
( T N 4 6 4 * )
Description/Recommendation
Continued on next page
T o f a r e n d
s w i t c h h a r d w a r e
555-233-123

Advertisement

Table of Contents