EXP-INTF (Expansion Interface Circuit Pack)
Table 10-295. TEST #336 Expansion Interface Reset Test — Continued
Error
Code
12026
1
2
555-233-123
Test
Result
ABORT
Expansion Interface circuit pack reset successfully. It
responded with an unknown reply to the query for the results of
its initialization tests.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, replace the circuit pack or
transceiver.
FAIL
The Expansion Interface did not successfully reset.
1. If the Expansion Interface circuit pack is in the EPN, the
EPN Maintenance Board may be holding the Expansion
Interface circuit pack reset. Attempt to rectify this condition
by executing the test maint P long command on the
maintenance board in the same EPN.
2. If Step #1 was not successful in releasing the Expansion
Interface circuit pack, temporarily remove the EPN
maintenance circuit pack.
3. Repeat the reset board PCSS command.
4. If reset continues to fail, replace circuit pack.
5. Insert EPN maintenance circuit pack if it was removed.
FAIL
The Expansion Interface circuit pack was successfully reset,
but it did not begin running after the reset.
1. If the Expansion Interface circuit pack is in the EPN,
temporarily remove the EPN maintenance circuit pack.
2. Repeat the reset board PCSS command.
3. Re-insert the EPN maintenance circuit pack if it was
removed.
Description/Recommendation
Continued on next page