Inads (Inads Link) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Object Repair Procedures

INADS (INADS Link)

MO Name (in
Alarm Log)
INADS
The INADS Link MO represents the software and communications link required by
the switch to make a call to the Initialization and Administration System (INADS).
The purpose of the INADS Link MO is to check the communications link between
the DEFINITY Generic 1 and INADS and verify that the alarm notification process
works correctly. An INADS technician can test the process remotely to verify that
alarms are reported to INADS, or a system technician may want to test the
connection while on-site at installation time or during subsequent service calls.
Although the INADS Link MO is never alarmed, the errors are logged. The errors
are only logged as a result of the test inads-link command being issued.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the INADS Link Test
description.
Short and Long Test Sequences
The test inads-link command is different from other test commands. This
command does not have a long or short option, and the test on the INADS Link
does not have an associated test number. When the command is different from
other test commands. This command does not have a long or short option, and
the test on the INADS Link does not have an associated test number. When the
test inads-link command is issued, the user immediately sees either the
"Command successfully completed" or "Command failed" message command is
issued, the user immediately sees either the "Command successfully completed"
or "Command failed" message.
10-912
Issue 4 May 2002
Alarm
Level
Initial Command to Run
none
test inads-link
Full Name of MO
INADS Link
555-233-123

Advertisement

Table of Contents
loading

Table of Contents