Avaya Definity SI Maintenance Manual page 1607

Table of Contents

Advertisement

EXT-DEV ADMIN? N (External Device Alarm)
Table 10-299. TEST #120 External Device Alarm Test — Continued
Error
Code
2029
2319
2320
2500
ANY
555-233-123
Test
Result
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The External Device Alarm has been activated by the external
device.
1. Clear the major alarm on the external device, and rerun
the test.
2. If the test still fails, then disconnect the External Device
Alarms from the Maintenance circuit pack and rerun the
test.
3. If the test still fails, then there is a problem with the
Maintenance circuit pack that is reporting the alarm. This
circuit pack should be replaced. There are failures that can
occur on Maintenance circuit pack's that will not be
detected by their respective maintenance, but which will
cause many environment tests to fail. If many environment
tests are failing, the suspect circuit pack should be
replaced and the test rerun.
PASS
If there is a problem with the external device, but the
Maintenance circuit pack connected to the device reports no
alarm, then the External Device may not be properly reporting
the problems or the External Device may not be properly
connected to the External Device.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-821

Advertisement