EXP-INTF (Expansion Interface Circuit Pack)
Table 10-293. TEST #242 Expansion Interface Lightwave
Error
Code
0
Expansion Interface Control Channel Test (#316)
If an Expansion Interface circuit pack is a Standby Expansion Interface circuit
pack (yellow LED off) or if the Expansion Interface is active in the PPN (yellow
LED on), this test queries the Expansion Interface circuit pack for its circuit pack
type and vintage information. If the Expansion Interface circuit pack is an Active
Expansion Interface circuit pack in the EPN (yellow LED on long, off short), the
Expansion Interface Control Channel Test checks to see if the Expansion
Interface circuit pack can communicate with other circuit packs in the EPN using
the EPNTDM Bus.
Table 10-294. TEST #316 Expansion Interface Control Channel Test
Error
Code
Result
ABORT
2000
ABORT
2100
ABORT
555-233-123
Transceiver Loop Around Test — Continued
Test
Result
NO
No board was detected by the test.
BOARD
1. Check the error log for wrong board (error 125) or no
board (error 131). Resolve either of these issues, if
applicable.
2. Check that the board is properly translated and inserted. If
so, check for hyperactivity (error 1538). If hyperactive, use
the reset board PCSS command.
3. Run the test again. If it fails, the ID chip on board may be
bad. Replace the board and retest.
Test
Internal system error
Response to the test was not received within the allowable time
period.
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
Description/Recommendation
Continued on next page
Issue 4 May 2002