Avaya Definity SI Maintenance Manual page 1706

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-334. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1(a)
0
Circuit pack removed or
SAKI Test (#53)
18(b)
0
busyout board UUCSS
23(c)
0
Board administered but not
inserted
125(d)
none
Wrong board
257(e)
65535
Control Channel Loop Test
(#52)
513(f)
4352
TN2302 On board hardware
4353
errors
4355
4356
4358
1025(g)
Any
FPGA Query Test (#1406)
1281(h)
Any
TSI Health Query Test
(#1406)
1538(i)
Any
Circuit pack is hyperactive
1793
Any
NIC Loss Of Signal
2049(j)
Any
PPC Sanity Query Test
(#1406)
2305(k)
Any
IP Address Update
2561(l)
Ping error
2817(m)
Any
Ethernet Hardware Query
Test (#1406)
3073(n)
Any
Circuit pack reset Test (#53)
3840,
Inconsistent downlink or
3841(o)
board error
3999(p)
Any
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
10-920
Issue 4 May 2002
Associated Test
Any
MIN/WRN
WARNING
WARNING
MINOR
MINOR
MINOR
MINOR
MINOR
MIN/WRN
Alarm
On/Off
Level
Board
Test to Clear Value
Any
test board UUCSS
OFF
OFF
release board UUCSS
OFF
add ds1 UUCSS
ON
ON
test board UUCSS l r
20
ON
ON
2
test board UUCSS l r 2
555-233-123