Maintenance Object Repair Procedures
Table 10-329. TEST #60 Hybrid Line Lamp Updates Test — Continued
Error
Code
0
Hybrid Line Audits Test (#61)
This is a series of three tests that are classified as audits. These audits abort if
attempted on an out-of-service station. The tests are as follows:
Switchhook Audit - This is an update of the SPE records according to the
circuit packs' records.
Bad Scan Inquiry - A message is sent uplink that contains a count that is
generated due to certain events relating to the data link conditions. This is
an indication of data transmission problems between the Hybrid circuit
pack and the voice terminal.
EPF Inquiry - The status of the Electronic Power Feed is sent uplink.
Possible conditions are: EPF-on-ok, EPF-off, EPF-no-load, and
EPF-on-overcurrent.
10-906
Issue 4 May 2002
Test
Result
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of
5 times.
PASS
Hybrid Line Lamp Updates completed successfully.
1. If complaints still exist, investigate by using other circuit
pack tests, and by examining the station, wiring, and
connections.
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Description/Recommendation
Continued on next page