Avaya Definity SI Maintenance Manual page 1532

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-281. TEST #1281 TCP/IP PING Test — Continued
Error
Code
Result
1125
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
2500
ABORT
10-746
Issue 4 May 2002
Test
Ethernet link not in service.
1. Verify Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the link is not in service, release the link using (release
link n or release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
Did not receive circuit pack test response within the allowable
time period.
1. Reset the circuit pack (busyout board UUCSS, reset
board UUCSS, and release board UUCSS).
2. If the test fails again, replace the circuit pack.
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Description/Recommendation
Continued on next page