Avaya Definity SI Maintenance Manual page 1664

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-316. TEST #1387 H.323 Signaling Group Ping Test — Continued
Error
Code
2100
ABORT
2500
ABORT
2800
ABORT
2801
ABORT
2802
ABORT
7, 89,
FAIL
1007
PASS
10-878
Issue 4 May 2002
Test
Result
The necessary system resources to execute the test could not
be allocated.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3times.
No CLAN in the same region.
1. Verify translations and retest.
No IP address defined.
1. Verify translations and retest.
Different IP address pinged than software had allocated for the
test.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
PING to the destination failed through this port because the
destination was down.
1. Verify that at least one destination reachable through
this port is "up". Once verified, execute test
sig-group grp# command to verify that the H.323
Signaling Group Ping Test (#1387) passes.
PING through this port was successful.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents