Avaya Definity SI Maintenance Manual page 1697

Table of Contents

Advertisement

HYB-LINE (Hybrid Line)
Table 10-331. TEST #62 Hybrid Line Ringer Update Test — Continued
Error
Code
0
555-233-123
Test
Result
PASS
Hybrid Station Ringer Update passed
1. If complaints still exist, investigate using other circuit
pack tests on this circuit pack, and by examining the
terminal, wiring, and connections.
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-911

Advertisement

Table of Contents
loading

Table of Contents