Avaya Definity SI Maintenance Manual page 1573

Table of Contents

Advertisement

EXP-INTF (Expansion Interface Circuit Pack)
Table 10-291. TEST #240 EI Local Loop Around Test — Continued
Error
Code
Result
2000
ABORT
2100
ABORT
1
FAIL
2
FAIL
3
FAIL
12
FAIL
21
FAIL
FAIL
555-233-123
Test
Response to the test request was not received within the
allowable time period.
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Loop back on TDM Bus A failed. Loop back on TDM Bus B
passed.
Loop back on TDM Bus B failed. Loop back on TDM Bus A
passed.
Loop back on both TDM Busses failed.
Loop back on TDM Bus B failed. Loop back TDM Bus A aborted
because the system could not allocate time slots.
Loop back on TDM Bus A failed. Loop back on TDM Bus B
aborted because the system could not allocate time slots.
The test tone was not detected correctly after being looped
through the Expansion Interface circuit pack.
1. If error type 2305 has been logged against the Expansion
Interface circuit pack in the last 5 minutes, this test could
have failed due to the associated slips. If this is the case, first
resolve the 2305 error, and then repeat test.
2. Run the tests for the Active Tone-Clock on the Port Network
that contains the indicted Expansion Interface circuit pack to
verify that dial-tone is being supplied.
3. If the tone-clock is healthy, repeat the short test on the
Expansion Interface circuit pack.
4. If this test continues to fail, replace Expansion Interface
circuit pack.
Description/Recommendation
Continued on next page