When The Security Sensor Detects A Signal; Calling To An Emergency Destination; When An Emergency Call Is Answered - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Internal Paging will only play the message when the targeted terminal is in an Idle state.
If an ordinary Internal Paging message is sent, the message is aborted and the watching
message is played.
A Warning message has a higher priority than a Watch message when both occur at same
time.
When using an external speaker, start and end tones are not supported.
When the security sensor detects a signal the following options can be set:
A Warning message is sent.
An Emergency call is sent.
A Warning message and an Emergency call are both sent.

Calling to an emergency destination:

The emergency number is set in Program 20-46-05.
Outside call routing uses Program 13-05-01.
If Program 13-05-01 is set to 0, outside call routing uses the settings in Program 14-06-01 and
search for data from route table 100 using order 4 in descending order. If Program 14-06-01 is
set to 0, outside calls are not supported.
If an outgoing call is set in a system, emergency calls cannot go through. When using outgoing
call restriction, Class 1 toll restriction is followed.
If all trunks are busy, the emergency call is not sent. If this occurs, Alarm Type 33 is used.

When an emergency call is answered:

Provide a VRS message to the destination.
After finishing the VRS message, start monitor operation which preprogrammed in Program
20-46-10. Also by pressing
monitor terminal is not idle status, an emergency call destination cannot start monitor and hear
no tone.
If a Watch or Warning message is sent to the destination and all VSR channels are busy, a
tone is played instead of displaying the VRS message.
If the VRS message is not recorded, a tone is played.
Barge-in is not allowed to outside call while monitoring.
A VRS message can be played from the extension's speaker only when the extension is
idle. But if a Watch or Warning message is requested while a normal page is being used,
normal paging stops and the Watch or Warning message is sent.
If a warning tone is provided instead of the VRS message, paging information is displayed
as a blank to the paging group terminal LCD.
If a Watch or Warning message happens during normal paging, normal paging stops and
the Watch or Warning message is sent.
A Warning message has a higher priority than a Watch message when both occur at same
time.
Activating or stopping sensor operations need to be set according to sensor specifications.
If an outgoing call restriction is set in a system, the number for the emergency call needs to
be pre-registered in the restriction allow table.
Auto outgoing call via leased line cannot go through when all trunks are busy.
When an emergency call destination is not answered, the system repeats the emergency
*
key from outside, it is possible to enable a two-way path. If the
1046