Tandem Trunking From Conference - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Guide to Feature Programming
Method A – Tandem Trunking from Conference:
Program
Program Name/Description
Number
Service Code Setup (for Service Access) –
11-12-57
Tandem Trunking
If the default service code (
Trunking is not acceptable, change the code as
required.
Basic Trunk Data Setup – Transmit Gain
14-01-04
Level for Conference and Transfer Calls
Select the Transmit CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Receive Gain
14-01-05
Level for Conference and Transfer Calls
Select the Receive CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Trunk-to-Trunk
14-01-13
Transfer
For each trunk that should be able to participate
in a tandem call, enter 1.
15-07-01
Programmable Function Keys
(Optional) Assign a function key for Transfer
(code 06).
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
20-07-11
Class of Service Options (Administrator
Level) – Forced Trunk Disconnect (analog
trunk only)
Turn Off or On an extension user ability to use
Forced Trunk Disconnect. This allows the
extension to disconnect an unsupervised
conference in progress.
20-11-14
Class of Service Options (Hold/Transfer
Service) – Trunk-to-Trunk Transfer
Restriction
Turn Off or On the Trunk-to-Trunk Transfer
Restriction. If enabled, Trunk-to-Trunk Transfer
is not possible.
20-11-21
Class of Service Options (Hold/Transfer
Service) – Restriction for Tandem Trunking
on Hang Up
Allow/Deny an extension user ability to set up a
tandem call automatically when they hang up.
MLT, SLT
0 ~ 9,
#
8) for Tandem
digits
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
0 = Disable
1 = Enable
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
Function Code) (Service Code
852 by default)
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
0 = Off
1 = On
0 = Allow
1 = Deny
1199
Input Data
*
#
,
Maximum of eight
*
99 (Appearance
Default
753
32 (0dB)
16 (-8dB)
1
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1~14 = 0
COS 15 = 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0

Advertisement

Table of Contents
loading

Table of Contents