Security; Warning Message (Watch Mode) - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Security

Description
This system supports the following built-in simple security features:

Warning Message (Watch Mode)

Automatically and periodically send the Watching (VRS) Message from built-In Speaker on
Multiline Terminal or external paging adapter during nightmode.
Enable to accommodate with 3rd Party PIR (Passive Infrared Sensor) or Emergency Button to
provide security feature such as Auto-Emergency Call with Warning (VRS) Message sending.
Remote Inspection
Automatically ring the terminal with preprogrammed schedule in order to check whether users
answer or not. If not answered, Emergency Call is placed to predefined destination automatically.
Conditions
Warning Message (Watch Mode)
Watch mode can provide Watching message in a preprogrammed interval via internal
paging group terminals during defined schedule such as night time.
When connected to the system the security sensor will receive sensor detections and send
a prepared warning message or emergency call to a preprogrammed destination.
When connecting security sensor, set Program 20-46-01 Sensor mode to 1 (On), the
security sensor can be connected to the detector circuit on the 2PGDAD. A maximum of
eight sensors can be connected.
Applied voltage when sensor is Off: 5V
Loop current when sensor is On: 14mA
When the system receives a detection signal from a contact on the 2PGDAD detector
circuit. The input circuit contact setting in Program 20-46-12 must match the circuit setting
in Program 10-41-01.
Watch mode can be started and stopped automatically using settings in Program 20-47-01.
Watch mode can be started and stopped manually using Service code (Program 11-12-63) or
function key (SC852:
press again to stop the message.
Security sensor can be started and stopped automatically using settings in
Program 20-48-01.
Security sensor can start and stop manually using Service code (Program 11-12-64) or
function key (SC852:
expires, then the function key turns red. The system can detect a signal from the sensor.
The Watching Message:
Is displayed after the timer in Program 20-44-04 expires.
Can be edited using the Service Code in Program 11-10-20.
Can be recorded up to a maximum of two minutes.
The Length of the watch message depends on the length of the recorded VRS message.
*
32) assignment. After 10 seconds a warning message is provided,
*
*
33). Function key (
33) blinks until the timer in Program 20-55-01
1045