For Answer Detection Of Analog Trunks; For The Warning Message - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

call the number of times specified in Program 20-46-08.

For Answer detection of Analog Trunks;

In case of answer supervision, when answer supervision is received, the system recognizes
the called party has answered.
In case of no answer supervision, after the inter digit timer has expired, the DTMF receiver
waits for the
key to be pressed. Then the system recognizes the called party has answered.
*
During remote monitoring, the outside lines cannot be disconnected until the timer in
Program 20-21-05 expires.

For the Warning message:

Watch mode operation uses the order set in internal paging.
The VRS message can be edited using Service code Program 11-10-20.
The maximum length of a recorded message is two minutes.
If multiple sensors are detected at the same time, the latest detected sensor's Warning
message is provided.
The warning message continues to play the same VRS message.
To cancel the Warning message use Security Sensor Reset Service Code Program 11-12-62.
When using external speaker, a start and end tone is not provided for any situation.
If, while playing a Warning message and the targeted internal or external paging group was
already playing another Warning message, the first Warning message is canceled. In this
case either the internal or external paging group was duplicated with the latest paging
group. An old Warning message stops both internal and external paging.
If the DND key is pressed at the called terminal while playing a Watch or Warning message,
the next message is not played because the terminal is determined to be busy. When the
terminal returns to an idle state, the message is played again.
An emergency call via analog trunk which has no disconnect signal, if Program 14-02-18 is
invalid the call cannot disconnect by trunk side.
In case of an emergency call the trunk key status is red. It is also red while monitoring or
speaking.
An emergency call goes through even if no trunk key is assigned to the terminal.
In case of using internal and external paging group same time, message will provided when
both paging groups are in idle status. If internal or external paging group is already used,
message will not provided.
In case of speaking status after monitor mode, monitored terminal key does not operate
except speaker key.
When the sensor malfunctions, use Security Sensor Reset Service Code programmed at
Program 11-12-62 to cancel the operation, stop warning message or stop emergency call.
During the Watch mode or Security sensor "On" state, if a system reset occurs these
modes automatically continue after boot up.
When sending a Warning message or placing an emergency call, if system reset occurs the
call state is cleared. Following a boot up, the Warning message or source placing an
emergency call will stop.
If security sensor detects a signal, display below sentence to terminal which set Program
20-08-23 data to 1.